Double Acting
Threaded plunger end with cap screw provides secure attachment of standard or custom built arms.
Porting is all on the top of the cylinder body for easy access, no need to modify fixtures to access cylinder end to unclamp.
BHC™ (Black Hard Coating) on the cylinder bodies helps prevent leaks caused by scoring and scratching, especially in the event of high side or "kick" loads which promote excessive scoring in many other brands.
U.S. Patent Nos. 5,820,118 6,886,820 B1
Specifications Specifications Model No. Swing Direction Cylinder Capacity (kN)* Vertical Clamping Stroke (mm) Total Stroke (Swing + Vertical) Body Thread Effective Piston Area (cm2) Oil Capacity (cm3) Retract Extend Retract Double Acting (D/A) Cylinders, actuated hydraulically both directions. 41-5005-23 41-5005-24 41-5005-26 Right Left Straight 4,9 19 31 M38 x 1,5 1,90 11,9 5,9 41-5011-23 41-5011-24 41-5011-26 Right Left Straight 11,6 34 51 M48 x 1,5 4,04 40,0 20,5
41-5005-23
41-5005-24
41-5005-26
Right
Left
Straight
4,9
19
31
M38 x 1,5
1,90
11,9
5,9
41-5011-23
41-5011-24
41-5011-26
11,6
34
51
M48 x 1,5
4,04
40,0
20,5
WARNING: Never allow swing arm to contact workpiece or fixture during rotation.
* Cylinder capacities are listed at 350 bar (35 MPa) maximum operating pressure with a standard VektorFlo® arm installed. See the Arm Length and Pressure Limitations graph for clamping force with various other arm lengths installed. The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate output force for your application, divide the cylinder capacity shown above by 350 bar (35 MPa), and multiply the resultant number times your system operating pressure to obtain the approximate clamping force for your application. (Actual force will vary slightly due to internal cantilever loading, friction loss, and/or return spring.)
NOTE: To allow for piece part height variations, it is recommended that the vertical travel be set at about 50% of the vertical stroke.
NOTE: To insure maximum service life and trouble-free operation, restrict fluid flow to the level indicated in the Clamp Time and Fluid Flow Rate chart.
Dimensions
41-5005-23 41-5005-24
41-5011-23 41-5011-24
All dimensions are in mm.
Order arms separately.